Current Position: Home >> PRODUCT >>  Flow meter >>  A类流量计

  • Describe
Product overview: Jk-dmf series mass flowmeter is based on Coriolis principle to realize direct and precise measurement of fluid mass flow, without any conversion or correction of pressure, temperature, viscosity, density, etc. Its structure is composed of sensor unit and transmitter unit. The instrument is designed and manufactured according to the national standard of intrinsically safe explosion-proof type, and the explosion-proof mark is Exd IB II CT5 GB. Coriolis mass flowmeter can directly measure the quality of fluid, with high precision (0.1% ~ 0.2), wide application range (can measure all kinds of non Newtonian fluid, slurry, suspension, high viscosity fluid, etc.), low installation requirements (not high requirements for the front and rear straight pipe section of the instrument), reliable and stable operation, low maintenance rate. Product features: 1. It can measure almost all fluids, including high viscosity liquid, mud and multiphase fluid; It can provide field mounted and rack mounted separate converters; High precision digital signal processing makes the measurement accurate and stable; The special detector isolation system greatly reduces the interference of external stress and vibration; The simple measuring flow path is convenient for automatic emptying and cleaning, and can be used in food industry; It can ensure high precision and high stability in large range; Accurate density measurement; easure the concentration of solution, suspension and emulsion (such as water content, pure oil calculation); Temperature range: - 200 ℃ - + 350 ℃; High performance based on microprocessor; Save the set parameters and cumulative measurement during power failure; High Definition LCD display; Different measuring tube materials can be selected; Provide en, ASME or JIS standard flange, or as required; principle: When a particle in a pipe with P as the center of rotation moves toward or away from the center of rotation, a consistent force will be generated. The principle is shown in Fig. 1 When a particle with mass δ m moves in a pipe with constant velocity V around a fixed point P and rotates at angular velocity ω, the particle will obtain two acceleration components The value of normal acceleration α R (centripetal acceleration) is equal to ω 2R and its direction is toward point P; The tangential acceleration α t (Coriolis acceleration), whose magnitude is equal to 2 ω V, is perpendicular to α R. According to Newton's second law of motion (force = mass x acceleration), to produce the Coriolis acceleration α T, a corresponding force must be applied in the direction of α T, which is equal to 2 ω V δ M. this force comes from the upward rotating pipe. The force acting on the pipe reversely, FC = 2 ω V δ m (hereinafter referred to as Coriolis force). In the figure, the fluid δ M = ρ a Δ x, so the Coriolis force can be expressed as: ΔFc=2ωvδm=2ωvρAΔx=2ωδqmΔx Where: A is the internal sectional area of the pipeline δqm=δdm/dt=vρA For a particular rotating pipe, its frequency characteristic is certain, Δ FC only depends on δ QM. Therefore, the mass flow can be measured directly or indirectly by measuring the Coriolis force exerted by the fluid flowing in the rotating pipe, which is the basic principle of mass flowmeter.
Scope of application: it is applicable to the measurement of mass flow or volume flow of liquid, gas, liquid-solid and gas-solid Measuring tube material: 316L stainless steel or HAC alloy Pressure rating: 2.5MPa, 4.0Mpa, other high pressure can be ordered specially. Medium temperature: - 50 ℃ ~ + 150 ℃ (special customization: maximum temperature + 350 ℃, minimum temperature - 200 ℃) Ambient temperature: sensor: - 40 ℃~ + 150 ℃, transmitter: - 20 ℃~ + 70 ℃ Flow measurement accuracy: ± 0.20%, ± 0.1% flow rate ± [(zero stability / flow value) × 100]% flow rate Density measurement accuracy: ± 0.002g/cm?, ± 0.001g/cm Repeatability: ± 0.10%, ± 0.05% flow rate ± [half (zero point stability / flow value) × 100]% flow rate Output signal: 4 ~ 20mA load resistance < 500 Ω (instantaneous flow or density optional); 0 ~ 10kHz instantaneous flow pulse signal; 485 communication signal Explosion proof sign: ex D IB II C T5 GB

Recommend

  • V-cone Flowmeter
    Jklv series V-cone Flowmeter
  • JKLW turbine flowmeter
    turbine flowmeter
  • Input type liquid level gauge
    JK-LT SERIES
  • Intelligent vortex flowmeter
    JKLU series vortex flowmeter
  • Share:

Copyright © 浙江精控仪表有限公司 All Rights Reserved. 浙ICP备18010485号